SDW CNF 13-Jun-97 MDI FLIGHT STATUS DISPLAY EXPLANATION ------------------------------------- (Found by typing: screen 12) Typical Snapshot of MDI Flight Status Screen ############################################################################### GMT: Wed Apr 9 21:21:49 1997 TM: MEDIUM MDI Flight Status(12) TM_STATE: RUNNING HR MODE: NO DATA DPC:46451fc0 SVM: 001419 HK1: 001422 HK2: 001418 SCI5K: 034104 SCI160K: 081720 POWER (A) ON 1.29 a DEP IP m+5pc1n 5.36 v Ref Time 49DE66F8h IP Status 48h m+5cm 5.48 v LOBT 49DE66F7h Error Stat 3000h m+5pc2n 5.33 v Cmd Count 28 Int Count 0B02h m+5ae 5.28 v 5K Mode 03h IP-DEP Bank 00h Motor Cur 0.00 a 5k Status 95h Error Count 36 OVEN ON SEQUENCE Error Code FE01h qtopts3n 35.6 c Seq Status 05h Opcode 01EAh mtopts5 35.5 c Seq Error 0003h DMA Mode 0000h OP/EP TEMPS Int Count 33 IP Que Add 0D55h qtopts2n (OP) 20.1 c FrmInSeq 56390 mtopts6 (CCD) -77.1 c Seq ID C64F5107h CAMPAIGN STATE ADDRESS mtopts1 (FW) 43.2 c Cam ID 0F5h Alt Enable ON 13 qtepts1n(PC1) 15.9 c Obs ID 107h Cam Flag ON 740 mtepts3 (PC2) 18.1 c REGISTERS New Flag OFF 740 ISS CLOSE OBS Frm (R0) 6 Chain Flag ON 740 PZT1 IN RANG 1.86 v Int Count (R2) 33 Chain Indx 1 PZT2 IN RANG 1.78 v VC ID (R3) 3 Term Flag OFF PZT3 IN RANG 1.92 v Cam Mode (R4) 1 New Prime OFF Xavg:2.27 Yavg:2.27 v Mag D/L (R5) 0 II Flag OFF 88 ############################################################################### Parameter Explanations ############################################################################### Banner Section ------------------------------------------------------------------------------- 1 GMT: Wed Apr 9 21:21:49 1997 TM: MEDIUM 2 MDI Flight Status(12) TM_STATE: RUNNING HR MODE: NO DATA DPC:46451fc0 3 SVM: 001419 HK1: 001422 HK2: 001418 SCI5K: 034104 SCI160K: 081720 ------------------------------------------------------------------------------- LINE COLUMN 1 Column 2 Column 3 ------------------------------------------------------------------------------- 4 POWER (A) ON 1.29 a DEP IP 5 m+5pc1n 5.36 v Ref Time 49DE66F8h IP Status 48h 6 m+5cm 5.48 v LOBT 49DE66F7h Error Stat 3000h 7 m+5pc2n 5.33 v Cmd Count 28 Int Count 0B02h 8 m+5ae 5.28 v 5K Mode 03h IP-DEP Bank 00h 9 Motor Cur 0.00 a 5k Status 95h Error Count 36 10 OVEN ON SEQUENCE Error Code FE01h 11 qtopts3n 35.6 c Seq Status 05h Opcode 01EAh 12 mtopts5 35.5 c Seq Error 0003h DMA Mode 0000h 13 OP/EP TEMPS Int Count 33 IP Que Add 0D55h 14 qtopts2n (OP) 20.1 c FrmInSeq 56390 15 mtopts6 (CCD) -77.1 c Seq ID C64F5107h CAMPAIGN STATE ADDRESS 16 mtopts1 (FW) 43.2 c Cam ID 0F5h Alt Enable ON 13 17 qtepts1n(PC1) 15.9 c Obs ID 107h Cam Flag ON 740 18 mtepts3 (PC2) 18.1 c REGISTERS New Flag OFF 740 19 ISS CLOSE OBS Frm (R0) 6 Chain Flag ON 740 20 PZT1 IN RANG 1.86 v Int Count (R2) 33 Chain Indx 1 21 PZT2 IN RANG 1.78 v VC ID (R3) 3 Term Flag OFF 22 PZT3 IN RANG 1.92 v Cam Mode (R4) 1 New Prime OFF 23 Xavg:2.27 Yavg:2.27 v Mag D/L (R5) 0 II Flag OFF 88 ############################################################################### Banner - Telemetry Status ------------------------- Line Label Expected Value Description 1 GMT: Current GMT GMT as derived from system time0 TM: MEDIUM Telemetry channel status. This will never read HIGH even if VC2/3 are active, but it could read LOW which would indicate that the S/C has had a serious problem. In LOW mode the EXP packet will take the place of the MDI HK1 and HK2 packets. Only the temperatures and voltages may be accurate for such a circumstance. 2 MDI Flight Status(12) Display name and number TM_STATE: RUNNING If the telemetry has been dropped by the ECS, but it is still running then you would see REQ ACKN. HR MODE: NO DATA sci160k data received at EOF (VC2) DPC: 46451fc0 8 digit hex data product code for VC2 high rate data. 3 SVM: count S/C SVM1 packet count for connection, will increment by 1 every 15 sec HK1: count MDI HK1 packet count for connection, will increment by 1 every 15 sec HK2: count MDI HK2 packet count for connection, will increment by 1 every 15 sec SCI5K: count MDI sci5k packet count for connection, will increment by approximately 24 every 15 sec SCI160K: count MDI sci160k packet count for connection, only increments during periods of VC2 contact (DEP Register R3 = 2) Column 1 - MDI Health Parameters -------------------------------- Line Label Sample Value Description 4 POWER ON S/C Bus A power status for MDI 1.29 a S/C Bus A Current as drawn by MDI. Should be between 1.0 and 1.6 amps. 5 m+5pc1n 5.36 v Power Converter 1 5 volt bus voltage monitored by S/C. Supplies the IP and camera. Should be between 5.1 and 5.6 volts. 6 m+5cm 5.48 v Power Converter 1 5 volt bus voltage monitored by MDI. Should be +/- 0.2 from m+5pc1n 7 m+5pc2n 5.33 v Power Converter 2 5 volt bus voltage monitored by S/C. Supplies the DEP, Application Electronics, mechanisms and heaters. Should be between 5.1 and 5.6 volts. 8 m+5ae 5.28 v Power Converter 2 5 volt bus voltage monitored by MDI. Should be +/- 0.2 from m+5pc2n 9 Motor Current 0.00 a Should not remain above 0.05 for more than two minutes. 10 OVEN ON Prime Oven heater controller status. 11 qtopts3n 35.6 c Oven temperature as monitored by S/C. Should be within 0.2 degC of 35.6 degC 12 mtopts5 35.5 c Oven temperature as monitored by MDI. Should be within 0.2 degC of 35.5 degC. 13 OP/EP TEMPS 14 qtopts2n 20.1 c Optics Package temperature as monitored by S/C. Should be in range of 10 to 35 degC. 15 mtopts6 -77.1 c CCD strap temperature as monitored by MDI. Should be in range of -105 to -60 degC. 16 mtopts1 43.2 c Front window temperature as monitored by MDI. Should be in range of 10 to 45 degC. 17 qtepts1n(PC1) 15.9 c Power Converter 1 temperature in the Electronics Package as monitored by S/C. Should be in range of -5 to 40 degC. 18 mtepts3 (PC2) 18.1 c Power Converter 2 temperature in the Electronics Package as monitored by MDI. Should be in range of 0 to 40 degC. 19 ISS CLOSE Image Stabilization System (Limb Tracker) control loop status. Should be closed except during ALT sequence magnetograms, once every 96 minutes. 20 PZT1 IN RANG 1.86 v ISS PZT1 actuator status as monitored by S/C and MDI monitored operating voltage. Voltage should be between 1 and 3 volts. 21 PZT2 IN RANG 1.78 v ISS PZT2 actuator status as monitored by S/C and MDI monitored operating voltage. Voltage should be between 1 and 3 volts. 22 PZT3 IN RANG 1.92 v ISS PZT3 actuator status as monitored by S/C and MDI monitored operating voltage. Voltage should be between 1 and 3 volts. 23 Xavg 2.27 v ISS average error in X direction measured in volts. Should be between 2.1 to 2.5 volts. 23 Yavg 2.27 v ISS average error in Y direction measured in volts. Should be between 2.1 to 2.5 volts. Column 2 - MDI DEP/Sequence Parameters -------------------------------------- Line Label Expected Value Description 4 DEP 5 Ref Time 482DE6D0h Reference time of last image, should (example) be within 40h of the LOBT. 6 LOBT 482DE6C7h Current on-board time. It will cycle (example) from about -30 to +30 w.r.t Ref Time in steps of 6-8 seconds. 7 Cmd Count xx Count of commands received by the DEP with a range of 0-255. 8 5K Mode 03h set by the telecommand MBDPMOD 00h - no 5k science (engineering mode) 01h - set to initialize, then returns to 00h 03h - sequence/science mode 04h - special limb tracker mode 9 5k Status 95h Typically 95, 02 or B2 First column should not be 4-7, c-f Second column should not be 0,7-f 00 indicates no 5k data is flowing 10 SEQUENCE 11 Seq Status xxh Sequence Status Codes (Normally see 03, 04 or 05) 00=SEQ_INACTIVE - stopped sequence (either due to a commanded halt or serious error) 01=SEQ_INIT - almost never seen (never last very long), DEP needs to be restarted 02=SEQ_WAIT_CAMERA - rarely seen, check if camera shutter is open or if data coming from camera (before any mechanism movement) 03=SEQ_ACTIVE - rarely seen, designates that the sequence is running 04=SEQ_WAIT_TIME - waiting for time mark (start of every minute), pictures taken based on this reference time 05=SEQ_WAIT_CON - waiting for configuration or the setup devices for next picture 12 Seq Error xxxxh Sequence Error Codes 0001=SEQ_NORMAL-Benign condition almost never seen 0002=SEQ_LATE-Benign condition almost never seen 0003=SEQ_BREAK-Normal sequence operating condition *0004=CAMERA_ERROR-not responding to Take A Picture (TAP) command or the shutter is stuck *0005=SEQ_WAIT - ? *0006=SEQ_STACK_DEPTH_EXCEEDED - error in stacking and unstacking routines *0007=SEQ_ILLEGAL_INSTR - load corruption, syntax error *0008=SEQ_STOP_CMD - actually need to send a sequence stop command to get this value *0009=ACCESS_VIOLATION - illegal address (outside of defined address area) *=serious error conditions! 13 Int Count 33 Number of observing intervals elapsed since last reset (i.e. how long since last set of magnetograms began) Currently counts up to 96. 14 FrmInSeq 56390 Number of camera frames taken in current sequence, increments 2 or 3 times per sample update (every 3 seconds during active sequence) 15 Seq ID C64F5107h Will begin with C4 during dynamics or ALT. Will begin with either C6 or C7 during campaigns. 16 CamID xxxh The ID number in hex for the current campaign as extracted from the sequence ID, will be 000 during dynamics or 3F0 at startup in some cases. 17 ObsID xxxh The ID in hex for the current observation as extracted from the sequence ID 18 REGISTERS 19 OBS Frm (R0) x Frame Number, increments from 1 to 20, at three second intervals. Only updated at 7 second interval so it will appear to skip some values. 20 Int Count(R2) xx Cycle number (see interval count, 0 - 96) 21 VC ID (R3) See DSN Virtual Channel number Schedule 0=no sci160k high rate (HR) 1=reserved for Dnyanesh Mathur, 2=HR - delivered to GSFC/EOF 3=HR - archived, not to EOF 22 Cam Mode (R4) dyn - 0 Campaign Flag, copy of R66 when cam - 1 campaign (right side) is active. 23 Mag D/L (R5) 1 Downlink of magnetograms: 2=in HR 160k, immediate downlink. 1=in MR 5k, downlink in medium rate sci5k channel for up to 24 minutes after end of ALT. 0=in HR 160k, downlink in two parts as second observable. (R5 is active if R4=0 and R3 does't = 0) Column 3 - MDI IP/Sequence Parameters ------------------------------------- Line Label Expected Value Description 4 IP 5 IP Status 48h 8 bit hardware register 1st nibble = DEP & IP interface state 4 = DEP & IP interface is happy 0 = DEP & IP interface is not happy 2nd nibble 8 = IP in run mode 0 = IP not on should be 48h when IP is nominal 6 Error Stat 3000h 3000 = PRIME 160k, Queue enabled 2800 = REDUNDANT 160k, Queue enabled 1000 = PRIME 160k, Queue disabled 0800 = REDUNDANT 160k, Queue disabled 07ff = Other IP error bits (seldom seen, but would indicate potentially serious problem). 7 Int Count 0B02h Count of the number of interupts to the (example) DEP. Updates approximately one per minute during dynamics. 8 IP-DEP Bank 00h Toggles every minute from 0 or 20 when sequence is running. 9 Error Count xx Count of IP errors. If the count increments but the Error Code, Opcode, DMA Mode and IP Que Addr stay the same then it was probably an EDAC page multibit error. 10 Error Code xxxh IP Errors 8071 = memory not available on DMA bus A 8074 = no end of transfer on DMA bus A FOOO = TM board hang. Could be caused by a loss of high rate clock to the MDI TM board (S/C moved out of MDI high rate mode without setting VC flag (R3) to zero) or by a compression error. FEnn = Bad frame to page nn (hex) 11 Opcode 01EAh Opcode of IP command which initiated error condition 12 DMA Mode 0000h Mode of the DMA during error. For a FOOO it records a count of the FOOO errors. 13 IP Que Add 0D55h address of Opcode in IP macro queue which caused error condition. 15 CAMPAIGN STATE ADDRESS 16 Alt Enable STATE ON Alt enable, alt sequence will run when the int count reaches the prescribed value (typically 96) ADDRESS 13 Address for the alt sequence. 17 Cam Flag STATE Dyn. - Off Cam. - On Campaign enable (ON or OFF), at the end of the current 1 minute sequence the DEP will begin running campaigns starting with the current address and will continue until the flag is turned off or the campaigns are completed and the terminate flag is set. ADDRESS See Plan Address of the current campaign if the Cam Flag is set or the next campaign if not. 0 is the address for the 14 minute cam_vc2_obs campaign. 18 New Flag STATE OFF New campaign enable, at the end of the current 1 minute sequence the new address campaign will be started. ADDRESS See Plan Address for new campaign when enabled. 19 Chain Flag STATE ON Chain campaign enabled, at the end of the current campaign, the chain address campaign will be started. ADDRESS See Plan Chain Address for next campaign when chain flag is ON 20 Chain Indx 1 Index into the chain address list (1-8) of the current chain address 21 Term Flag STATE Dny - On Terminate campaign after one iteration Camp - Off 22 New Prime STATE OFF At the end of the 1 minute sequence the DEP will start a new observation frame list for the prime sequence. 23 II Flag STATE OFF Intra-Instrument campaign enable. ADDRESS 88 Address for II campaign when enabled. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~