# Name: M_CCDSPT # # Date: # # created: 09 01 1994 SDW # revisions: # # Change Description # # None # # MDI Author: Scott Williams 415-725-0482 # # Description # # This procedure configures the set point for the Operational CCD heater # controller. # # Parameters # # 1) P1 - set point value, 3 bits (0 to 7) where 0 is no power and # 7 is maximum power # # Intended Use # # Setting the MDI Operational CCD controller set point # # Duration # # ? # # Requirements and Constraints # # MDI in SLEEP or higher mode. Medium rate telemetry support required for # duration of power on sequence. MDI Operator on station to support # verification of procedure. MDI operator verification required for # each step before continuing. # # Steps # # Step Description Command Monitor Value # record MDI current, either MIPWA <1.5 # or MIPWB # 2 HOC set point to P1 mbhcmspt mkhcmspt P1 # mbhcmspt P1 # 3 record MDI current, either MIPWA +0.3 # or MIPWB # 4 record CCD temperature QTMI1D # 5 end of procedure