# Name: M_HCMOFF # # Date: # # created: 09 01 1994 SDW # revisions: # # Change Description # # None # # MDI Author: Scott Williams 415-725-0482 # # Description # # This procedure powers off the CCD decontamination heater # # Intended Use # # Powering off the CCD decontamination heater # # Duration # # ? # # Requirements and Constraints # # MDI in SLEEP or higher mode. Medium rate telemetry support required for # duration of power on sequence. MDI Operator on station to support # verification of procedure. MDI operator verification required for # each step before continuing. # # Steps # # Step Description Command Monitor Value # 1 record MDI current, either MIPWA <1.5 # or MIPWB # 2 HCM CCD decontamination heater on mbpwhcmof mkpwhcm "OFF" # 3 record MDI current, either MIPWA -0.3 # or MIPWB # 4 record CCD temperature QTMI1D # 5 end of procedure