# Name: M_HTRCNFG # # Date: # # created: 08 11 1994 SDW # revisions: # # Change Description # # None # # MDI Author: Scott Williams 415-725-0482 # # Description # # This procedure configures set points for the Optics Package, # Operational CCD heater, and Decontamination CCD heater following # completion of the CCD decontamination period. # # Intended Use # # Setting the MDI Operational CCD and optics package heater # controller set points following CCD decontamination. # # Duration # # ? # # Requirements and Constraints # # MDI in SLEEP or higher mode. Medium rate telemetry support required for # duration of power on sequence. MDI Operator on station to support # verification of procedure. MDI operator verification required for # each step before continuing. # # Steps # # Step Description Command Monitor Value # 1 record MDI current, either MIPWA <2.0 # or MIPWB # 2 HOC set point to 0 (111) mbhcmspt mkhcmspt 0 # mbhcmspt 0 # 3 record MDI current MIPWA # MIPWB # 4 HOP set point to 64 (0100 0000) OPH3 mbhopspt mkhopspt 64 # mbhopspt 64 mkhoph2 "OFF" # mkhoph3 "ON" # 5 record MDI current MIPWA # MIPWB # 6 CCD decontamination heater off mbpwhcmof mkpwhcm "OFF" # mbpwhcmof # 7 record MDI current MIPWA # MIPWB # 8 end of procedure