# Name: M_OFFSCA # # Date: # # created: 08 09 1994 SDW # revisions: # # Change Description # # MDI Author: Scott Williams 415-725-0482 # # Description # # This procedure powers down the MDI instrument to the OFF state from # spacecraft bus A in a controlled manner. The initial mode should be # SAFE and the final mode will be OFF. # # Intended Use # # Controlled power down of MDI instrument from SAFE to OFF mode # # Duration # # ? # # Requirements and Constraints # # MDI in SAFE mode. Medium rate telemetry support required for # duration of power down sequence. MDI Operator on station to support # verification of procedure. MDI operator verification required for # each step before continuing. # # Steps # # Step Description Command Monitor Value # 1 verify front door status mkfdmtr1 # mkfdmtr2 # mkfdopn1 # mkfdopn2 # 2 inquire with MDI and close door if M_FDCLOSE # required # 3 inhibit limit monitoring # 4 configure MDI for OBS mode lobsmode # 5 reset shutter mbshrs # 6 AM power off mbpwamof mkpwam "OFF" # 7 FD power off mbpwfdof mkpwfd "OFF" # 8 limb tracker power off mbpwltof mkpwlt "OFF" # 9 CAL2 power off mbpwc2of mkpwc2 "OFF" # 10 CAL1 power off mbpwc1of mkpwc1 "OFF" # 11 PAW power off mbpwpaof mkpwpa "OFF" # 12 MTM2 power off mbpwm2of mkpwm2 "OFF" # 13 MTM1 power off mbpwm1of mkpwm1 "OFF" # 14 shutter power off mbpwshof mkpwsh "OFF" # 15 camera power off mbpwcmof mkpwcm "OFF" # 16 IP power off mbpwipof mspwipn "OFF" # mspwipr "OFF" # mkpwip "OFF" # 17 set TM select 1 mbpwtm1o mstmseln "1" # 18 ALL power off mcallofn mspwdpn "OFF" # mspwaen "OFF" # 19 record MDI current MIPWA ~0. # MIPWB ~0. # 20 switch power converters to B bus mcrc1bn msrc1n "B" # mcrc2bn msrc2n "B" # mcpc1bn mspc1n "B" # mcpc2bn mspc2n "B" # 21 reset relays on mcallonn # 22 s/c bus A power off KNMPWAFN MSPWA "OFF" # MSPWB "OFF" # 23 switch prime power converters to A bus mcpc1an mspc1n "A" # mcpc2an mspc2n "A" # 24 record MDI current MIPWA ~0. # MIPWB ~0. # 25 end of procedure