# Name: M_ON # # Date: # # created: 08 09 1994 SDW # revisions: # # Change Description # # MDI Author: Scott Williams 415-725-0482 # # Description # # This procedure powers up the MDI instrument with primary # HR telemetry initialized in the IP. The initial mode should be OFF # and the final mode will be SAFE. # # Intended Use # # Controlled initial power on of MDI to bring the instrument from OFF # to SAFE mode # # Duration # # ? # # Requirements and Constraints # # MDI in OFF mode. Medium rate telemetry support required for # duration of power on sequence. MDI Operator on station to support # verification of procedure. MDI operator verification required for # each step before continuing. # # Steps # # Step Description Command Monitor Value # 1 primary power on M_PCONSCA # 2 set voltage limits M_VLIMIT # 3 set temperature limits M_TLIMITON # 4 CCD and OP htr on M_HTRON # 5 Establish warm up set points M_HTRDECON # 6 prime oven heater on M_OVENON # 7 image processor power on M_IPON # 8 CCD camera power on M_CMON # 9 mechanisms power on M_MCHSON # 10 limb tracker power on M_LTON # 11 record MDI current MIPWA <2.0 # MIPWB ~0.0 # 12 end of procedure