# Name: M_OVENMON # # Date: # # created: 08 15 1994 SDW # revisions: # # Change Description # # None # # MDI Author: Scott Williams 415-725-0482 # # Description # # This procedure initializes s/w monitoring on the Prime Oven heater # controller. # # Intended Use # # Initiates s/w monitoring of MDI primary optics oven heater controller # following initial capture to stabil operating temperature. # # Duration # # ? # # Requirements and Constraints # # MDI in SLEEP or higher mode. Medium rate telemetry support required for # duration of sequence. MDI Operator on station to support # verification of procedure. MDI operator verification required for # each step before continuing. This procedure should be completed # as soon as possible following MDI power on. # # Steps # # Step Description Command Monitor Value # 1 set max oven temp mbovnmax mkovnmax 204 # mbovnmax 204 # 2 set oven monitoring time 1 minute mbhpomtw mkhpomtw 1 # mbhpomtw 1 # 3 set oven monitoring on mbhpomon mkhpomon "ON" # mbhpomon # 4 record MDI current, either MIPWA <1.3 # or MIPWB # 5 end of procedure