# Name: M_OVENSPT # # Date: # # created: 09 01 1994 SDW # revisions: # # Change Description # # None # # MDI Author: Scott Williams 415-725-0482 # # Description # # This Procedure sets the prime oven set point # # Parameters # # 1) P1 - prime oven set point, 3 bit value (0 to 7) where 0 corresponds # to approximately 33 degC and 7 corresponds to approximately 41 degC. # # Intended Use # # Establish prime oven set point for thermal control # # Duration # # ? # # Requirements and Constraints # # MDI in SLEEP mode. Medium rate telemetry support required for # duration of power on sequence. MDI Operator on station to support # verification of procedure. MDI operator verification required for # each step before continuing. # # Steps # # Step Description Command Monitor Value # 1 record MDI current, either MIPWA +0.4 # or MIPWB # 2 HPO set point to P1 mbhpospt mkhpospt P1 # tcblock mbhpospt P1 # 3 record MDI current, either MIPWA +0.4 # or MIPWB # 4 record oven temperature mtopts4 # mtopts5 # 5 end of procedure