# Name: M_SUBHTROFF # # Date: # # created: 09 01 1994 SDW # revisions: # # Change Description # # MDI Author: Scott Williams 415-725-0482 # # Description # # This procedure powers off the S/C powered substitution (non-operational) # heaters for the MDI optics package # # Intended Use # # Power off MDI optics package substitution heaters # # Duration # # ? # # Requirements and Constraints # # MDI in any mode. Should not be disabled if MDI optics package heaters are # not operating. Contact MDI operator as soon as possible. # OP temperature must be monitored within strict limits to avoid damage to # MDI optics. # # Steps # # Step Description Command Monitor Value # 1 enable s/c powered substitution KNQM1FN QSM1 "OFF" # heaters for MDI thermal control KNQM2FN QSM2 "OFF" # KNQM3FN QSM3 "OFF" # 2 record substitution heater current QIM3 # 3 record OP temperatures QTMI1A # QTMI1B # QTMI1C # 4 end of procedure