# Name: M_TLM2IP # # Date: # # created: 08 15 1994 SDW # # Change Description # # MDI Author: Scott Williams 415-725-0482 # # Description # # This procedure configures the IP to use the redundant high rate telemetry # interface (board 2). # # Intended Use # # Set the IP to use redundant high rate telemetry board 2. # # Duration # # ? # # Requirements and Constraints # # MDI in SAFE mode following successful performances of M_TLM2ON and # M_TLM2DEP to power up redundant high rate TLM board and configure DEP # for its use. S/C configured for redundant high rate telemetry. # High rate rate telemetry support required for duration of IP configuration # sequence and high rate TLM checkout. MDI Operator on station to support # verification of procedure. MDI operator verification required for # each step before continuing. # # Steps # # Step Description Command Monitor Value # 1 load IP patch to use redundant high mbdpml rate tlm into DEP memory mbdpml 0x2000 2 0x200 0x60e4 # 2 load IP patch into IP wcs mbiplwcs mbiplwcs 1 0x2000 2 0 0 0 0 0 0 0 0 0 0 0 4 # 3 reload camera header mbcmhdr1 mbcmhdr1 0x4040 0x4040 0 1 # 4 end of procedure