ITEMS:enable - (M,A) Enable limit checking for 1 or all parameters SEL:enable MAN:enable, SYN:ena[ble] all | par_name ITEMS:expect - (M,A) Set an expected status text strfor a digital parameter SEL:expect MAN:expect, SYN:exp[ect] par_name "string" count ITEMS:getint - (M,A) Get and display/store counter or register parm. value SEL:getint MAN:getint, SYN:geti[nt] par_name ITEMS:getmon - (M,A) Get and display/store the limit monitoring state SEL:getmon MAN:getmon, SYN:getm[on] par_name ITEMS:getraw - (M,A) Get and display/store a raw parameter value SEL:getraw MAN:getraw, SYN:getraw par_name ITEMS:getreal - (M,A) Get and display/store an analog parameter value SEL:getreal MAN:getreal, SYN:getr[eal] par_name ITEMS:inhibit - (M,A) Inhibit limit checking for 1 or all parameters SEL:inhibit MAN:inhibit, SYN:inhi[bit] all | par_name ITEMS:limit - (M,A) Set limit checking parameters for a database parameter SEL:limit MAN:limit, SYN:li[mit] par_name [a_l r_l r_h a_h count] | [-c r_delta a_delta count] ITEMS:patch - (M) Change database parameters SEL:patch MAN:patch, SYN:pa[tch] [calib | curve | loc | action] (See Manual Page for options) ITEMS:report - (M,A) Display detailed limit messages for a parameter SEL:report MAN:report, SYN:rep[ort] on | off all | par_name ITEMS:setpat - (M,A) Set a pattern to compare against a telemetry packet SEL:setpat MAN:setpat, SYN:setp[at] hk1|hk2|sc1|sc2|sc4|sci5k|sci160k start stop base ITEMS:table - (M) Display a database table SEL:table MAN:table, SYN:ta[ble] ootc|blktc|parm|tx|ca|pd_de|pd_co|pca|pc_di|dct|resp|status|dpc ITEMS:tmpat - (M,A) Enable compare of a pattern against a telemetry packet SEL:tmpat MAN:tmpat, SYN:tmp[at] hk1|hk2|sc1|sc2|sc4|sci5k|sci160k on | off