Limits that Cause Thermal Reconfigurations (TR) ----------------------------------------------- (all these temperatures are monitored and if they hit yellow limits the FOT will notify us) Mnemonics the FOT monitors for TR Red Limits How monitored for TR --------------------------------------------------------------------- qtmi1a (qtopts1n) 5/40 redundant for qtmi1b OP Radiator qtmi1b (qtopts2n) 5/40 * nominal temp for TR OP Structure qtmi1c (qtopts3n) 5/43 not monitored for TR Filter Oven qtmi1d (qtopts4n) -110/45 not monitored for TR CCD Radiator qtmi2 (qtepts1n) -5/45 * nominal for TR Primary Converter1 qtmr1 0/40 not monitored for TR Reference Point under OP qtmr2 0/40 redundant for qtmi2 Reference Point under EP * qtmi1b and qtmi2 cause a spacecraft thermal reconfiguration if they hit a red limit Redundant temperatures are not monitored unless we tell FOT that the nominal one doesn't work and they should monitor the redundant temperature.