EBZ & CED Nov 98 OP HEATERS Not yet approved by RIB ---------- - There are 3 OP heaters - 1 variable and 2 fixed. - Send tcb mbhopspt 63 to switch on heater 1 to full power mkpwhop goes to ON mkhopspt goes to 63 You can set this for less than 63 and mkpwhop will still say ON - The 64s bit of HOPSPT controls heater #3 (according to the screen telemetry) Send tcb mbhopspt 127 to switch on heater 3 mkhoph3 goes to ON - The 128s bit controls heater #2 Send tcb mbhopspt 191 to switch on heater 2 mkhoph2 goes to ON - Heater circuits 1, 2, and 3 each have four identical patch heaters in parallel, and should therefore have roughly the same current draw and heat input to the OP. - There's a master switch that controls all the OP package heaters' power. The commands to switch it on and off are: MBPWHOPN MBPWHOPF