PROC F_FL_CT_PHVL1 GOTO BEGIN ; ;#*********************************************************************** ;# ****PROCEDURE HEADER**** ;# ;# 1.0 Introduction ;# ;# 1.1 FOT Name: F_FL_CT_PHVL1 ;# MMS-F Name: ;# SUM Issue: ;# Simulator Validation Status ;# ;# 1.2 Date Created: 01-Nov-95 heg ;# ;# ;# 1.3 Change Description: ;# ;# ;# 1.4 Point of Contact: ;# Author: ;# H.Gruenwaldt MPAe Lindau (49) 5556-979 413 ;#*********************************************************************** ;# 2.0 Description ;# ;# 2.1 -->> Narrative Description <<-- ;# ** MPAe - CTOF AUTHORIZATION STRICTLY REQUIRED ** ;# PURPOSE: set HVPS LIMIT to level: PARAMETER ;# ;# 2.2 Intended Use: ;# ;# 2.3 Duration: TBD ;# ;# 2.4 References: ;# ;#*********************************************************************** ;# 3.0 Instructions for Use: ;# ;# 3.1 Parameters Required (hex) ;# ;# 0100: 4 kV ;# 0101: 10 kV ;# 0102: 15 kV ;# 0103: 19 kV ;# 0104: 23 kV ;# 0105: 26 kV ;# 0106: 28 kV ;# 0107: 30 kV ;# ;# 3.2 Critical Activities ;# ;# ;# ;# 3.3 Special Constraints or Activities ;# Max. time: 30 sec between the two commands of the procedure ;# ;# ************************************************************************* ;# 4.0 STEPS: BEGIN: IF (P@CMD_STATE#TELECOMMAND = "AVAILABLE") THEN ELSE /CLEAR ;Clearing the Command Buffer. ENDIF LOCAL PARHV ASK "WHAT HVPS VOLTAGE LIMIT DO YOU ALLOW, INTEGER, [KV] ?"PARHV IF (PARHV = 4) THEN /FBCENA /FBCLIMHV,0100 ;set HVPS limit to level 0, 4 kV WAIT ;VERIFY BUFFER Contents /SEND ELSE ENDIF IF (PARHV = 10) THEN /FBCENA /FBCLIMHV,0101 ;set HVPS limit to level 1, 10 kV WAIT ;VERIFY BUFFER Contents /SEND ELSE ENDIF IF (PARHV = 15) THEN /FBCENA /FBCLIMHV,0102 ;set HVPS limit to level 2, 15 kV WAIT ;VERIFY BUFFER Contents /SEND ELSE ENDIF IF (PARHV = 19) THEN /FBCENA /FBCLIMHV,0103 ;set HVPS limit to level 3, 19 kV WAIT ;VERIFY BUFFER Contents /SEND ELSE ENDIF IF (PARHV = 23) THEN /FBCENA /FBCLIMHV,0104 ;set HVPS limit to level 4, 23 kV WAIT ;VERIFY BUFFER Contents /SEND ELSE ENDIF IF (PARHV = 26) THEN /FBCENA /FBCLIMHV,0105 ;set HVPS limit to level 5, 26 kV WAIT ;VERIFY BUFFER Contents /SEND ELSE ENDIF IF (PARHV = 28) THEN /FBCENA /FBCLIMHV,0106 ;set HVPS limit to level 6, 28 kV WAIT ;VERIFY BUFFER Contents /SEND ELSE ENDIF IF (PARHV = 30) THEN /FBCENA /FBCLIMHV,0107 ;set HVPS limit to level 7, 30 kV WAIT ;VERIFY BUFFER Contents /SEND ELSE ENDIF ;# ;#*********************************************************************** ;# 5.0 Final Constraints ;# ;# TBD ;# ;#*********************************************************************** ENDPROC