PROC F_FL_M_MODIFC ;VERSION 0 IF(P@NRT_STATE#TELECOMMAND = "ENABLED")THEN /NRT TPUT PAUS ELSE ENDIF GOTO BEGIN ; ;#*********************************************************************** ;# ****PROCEDURE HEADER**** ;# ;# 1.0 Introduction ;# ;# 1.1 FOT Name: F_FL_M_MODIFC ;# MMS-F Name: ;# SUM Issue: MTOF Flight Procs Version 09-OCT-95 (part 1) ;# Simulator Validation Status: None. ;# ;# 1.2 Date Created: 03-OCT-95 ;# Revision: ;# ;# 1.3 Change Description: ;# ;# None. ;# ;# 1.4 Point of Contact: CCAZEAU ATSC/SOHO 286-6374 ;# FOT Author: BSAPPER ATSC/SOHO 286-4799 ;# CELIAS Author: AGALVIN UMD 301-405-6208 ;# ;#*********************************************************************** ;# 2.0 Description ;# ;# 2.1 Narrative Decription ;# ;# PUT MTOF IN INFLIGHT CALIBRATION MODE, SET MTOF HIGH ;# VOLTAGES (EXCEPT MCPS,HPS) TO OFF, DISABLED, LIMIT/DELTA=0/0 ;# ;# 2.2 Intended Use: ;# ;# Put CELIAS MTOF sensor into IFC, high voltages ;# that are affected placed in safe, known (default) ;# configuration. IFC is the InFlight Calibrator. ;# ;# 2.3 Duration: TBD ;# ;# 2.4 References: ;# ;#*********************************************************************** ;# 3.0 Instructions for Use: ;# ;# 3.1 Parameters Required ;# ;# None ;# ;# 3.2 Critical Activities ;# ;# IF MTOF HAS BEEN IN "POWER OFF" MODE WITH MTOF NON-OPS ;# HEATER(S) ON, THEN HEATER CONFIGURATION SHOULD BE ;# CHECKED BY FOT. IF NOT BAKE OUT, HEATERS SHOULD ;# BE OFF WHEN MTOF IS POWERED ON. ;# ;# 3.3 Special Constraints or Activities ;# ;# High voltages may be affected. Contact experimenter. ;# ;# ************************************************************************* ;# 4.0 STEPS: BEGIN: IF(P@CMD_STATE#TELECOMMAND = "AVAILABLE") THEN ELSE /CLEAR ;Clearing the Command Buffer. ENDIF ;# 4.1 Set affected MTOF high volages to level 0 (not MCPs or HPS!) WAIT ;NOTE VALUE OF FSDTCOK (command OK counter) /FBMPE,0000 ;PM E/Q power supply to level 0 /FBMWE,0000 ;MAIN WAVE power supply to level 0 /FBMVF,0080 ;MAIN Vf power supply to level 128 WAIT ;VERIFY BUFFER CONTENTS /SEND WAIT ;VERIFY FSDTCOK HAS INCREASED BY 3. NOTE NEW VALUE. ;# 4.2 Set affected MTOF high voltage limits and deltas to 0 /FBMLIMPE,0000 ;PM E/Q power supply delta/limit = 0,0 /FBMLIMWE,0000 ;MAIN WAVE power supply delta/limit = 0,0 /FBMLIMVF,0000 ;MAIN Vf power supply delta/limit = 0,0 WAIT ;VERIFY BUFFER CONTENTS /SEND WAIT ;VERIFY FSDTCOK HAS INCREASED BY 3. NOTE NEW VALUE. ;# 4.3 Disable affected MTOF high voltages /FBMDISI,000E ;disable MTOF PEQ,WEQ,VF high voltages WAIT ;VERIFY BUFFER CONTENTS /SEND WAIT ;VERIFY FSDTCOK HAS INCREASED BY 1. ;# 4.4 Place MTOF in IFC mode /FBMMOD4 ;MTOF IFC mode WAIT ;VERIFY BUFFER CONTENTS /SEND WAIT UNTIL(P@FSDMODM = "IFC") WAIT UNTIL(P@CMD_STATE#TELECOMMAND = "AVAILABLE") ;#*********************************************************************** ;# 5.0 Final Constraints ;# ;# CONFIRM MTOF NON-OPS HEATERS STATUS. CONFIRM HV STATUS. ;# ;#*********************************************************************** IF(P@NRT_STATE#TELECOMMAND = "PAUSE-ENAB")THEN /NRT TPUT RSUM /CMSMSG,CELIAS,'Procedure F_FL_M_MODIFC has completed' ELSE ENDIF ENDPROC