PROC F_FL_M_WMT120 ;VERSION 1 IF(P@NRT_STATE#TELECOMMAND = "ENABLED")THEN /NRT TPUT PAUS ELSE ENDIF GOTO BEGIN ; ;#*********************************************************************** ;# ****PROCEDURE HEADER**** ;# ;# 1.0 Introduction ;# ;# 1.1 FOT Name: F_FL_M_WMT120 ;# MMS-F Name: ;# SUM Issue: ;# Simulator Validation Status: ;# ;# 1.2 Date Created: 01-OCT-95 ;# Revision: ;# ;# 1.3 Change Description: ;# ;# None. ;# ;# 1.4 Point of Contact: CCAZEAU ATSC/SOHO 286-6374 ;# FOT Author: BSAPPER ATSC/SOHO 286-4799 ;# CELIAS Author: AGALVIN UMD 301-405-6208 ;# ;#*********************************************************************** ;# 2.0 Description ;# ;# 2.1 Narrative Decription ;# ;# PUT MTOF IN STANDBY MODE, STOF AND CTOF IN POWER OFF. ;# RUN MTOF WAX MOTOR FOR 120 SECONDS. ;# ;# 2.2 Intended Use: ;# ;# Open MTOF cover using wax actuator motor for 120 sec. ;# ;# 2.3 Duration: TBD ;# ;# 2.4 References: ;# ;#*********************************************************************** ;# 3.0 Instructions for Use: ;# ;# 3.1 Parameters Required ;# ;# None ;# ;# 3.2 Critical Activities ;# ;# IF THE DPU, CTOF, MTOF, STOF POWER STATE IS ;# CHANGED DURING THIS PROCEDURE, THE FOT SHOULD ;# CHECK THE APPROPRIATE NON-OPS HEATER(S) :# CONFIGURATION(S). ;# ;# CELIAS MUST BE IN THE POWER ON STATE. STOF AND CTOF ;# MUST BE IN, OR PLACED IN, A POWER OFF CONFIGURATION. ;# ;# WAX ACTUATOR COMMAND IS "CRITICAL". ;# ;# 3.3 Special Constraints or Activities ;# ;# Written or ONSITE verbal authorization by CELIAS ;# representative required for use of FBMOPT1 command. ;# CELIAS MTOF representative must be available. ;# ;# Status of MTOF,STOF,CTOF non-ops heater(s) should be ;# discussed with CELIAS representative. ;# ;# Thermal parameters need to be monitored for ;# several minutes before, during, and several minutes ;# after procedure. Printouts requested. ;# CELIAS current needs to be monitored before, during, ;# and after procedure. Printouts requested. ;# ;# ************************************************************************* ;# 4.0 STEPS: BEGIN: IF(P@CMD_STATE#TELECOMMAND = "AVAILABLE") THEN ELSE /CLEAR ;Clearing the Command Buffer. ENDIF ;# 4.1 CONFIRM OR PLACE ALL SENSORS IN DESIRED MODE IF(P@FSDMODC = "Power Off")THEN WRITE "**** CTOF SENSOR IS OFF *****" ELSE WRITE "**** CTOF SENSOR APPEARS TO BE ON *****" ASK "DO YOU NEED TO TURN OFF CTOF?" ANSWER = %UPPER(ANSWER) IF (ANSWER = "Y")THEN /FBCMOD0I ;CTOF power off, immediate execution WAIT ;VERIFY BUFFER CONTENTS /SEND WAIT UNTIL (P@FSDMODC = "Power Off") ENDIF ENDIF IF(P@FSDMODS = "Power Off")THEN WRITE "**** STOF SENSOR IS OFF *****" ELSE WRITE "**** STOF SENSOR APPEARS TO BE ON *****" ASK "DO YOU NEED TO TURN OFF STOF?" ANSWER = %UPPER(ANSWER) IF (ANSWER = "Y")THEN /FBSMOD0I ;STOF power off, immediate execution WAIT ;VERIFY BUFFER CONTENTS /SEND WAIT UNTIL (P@FSDMODS = "Power Off") ENDIF ENDIF IF(P@FSDMODM = "Standby")THEN WRITE "**** MTOF SENSOR IS ON, IN STANDBY MODE *****" ELSE WRITE "**** MTOF SENSOR IS NOT IN STANDBY MODE *****" ASK "DO YOU NEED TO PUT MTOF INTO STANDBY MODE?" ANSWER = %UPPER(ANSWER) IF (ANSWER = "Y")THEN /FBMMOD1I ;MTOF standby mode, immediate execution WAIT ;VERIFY BUFFER CONTENTS /SEND WAIT UNTIL (P@FSDMODM = "Standby") ENDIF ENDIF WAIT UNTIL (P@FSDSPM1 = "On") WAIT UNTIL (P@FSDSPC1 = "Off") WAIT UNTIL (P@FSDSPS1 = "Off") ;# 4.2 MTOF WAX MOTOR ACTIVATION ;NOTE VALUE OF CELIAS CURRENT (about 290 mA?). PRINT OUT. ;NOTE VALUE OF MTOF TEMPERATURES. PRINT OUT. WAIT ;CONFIRM WITH EXPERIMENT REPRESENTATIVE TO PROCEED. /FBMOPT1,0302 ;MTOF wax motor for 770 units = 120 seconds WAIT ;VERIFY BUFFER CONTENTS /SEND ;VERIFY CELIAS CURRENT GOES UP TO ABOUT 630 mA, AND WAIT ;PRINT OUT DISPLAY. ASK "IS EMERGENCY WAX MOTOR OFF COMMAND REQUIRED?" ANSWER = %UPPER(ANSWER) IF (ANSWER = "Y")THEN /FBMOPT1,0003 ;half second cmd to supercede 120 second cmd WAIT ;VERIFY BUFFER CONTENTS /SEND ENDIF WAIT UNTIL (P@FSDSPM2 = "Off") ;VERIFY CELIAS CURRENT DROPS TO ABOUT 290 mA, AND WAIT ;PRINT OUT DISPLAY. WAIT UNTIL(P@CMD_STATE#TELECOMMAND = "AVAILABLE") ;#*********************************************************************** ;# 5.0 Final Constraints ;# ;# CONFIRM MTOF NON-OPS HEATERS STATUS. ;# ;# CONTINUE MONITORING MTOF TEMPERATURES FOR AT LEAST 30 MINUTES. ;# ;# VERIFICATION OF MTOF COVER OPENING MUST BE ESTABLISHED BY ;# MTOF REPRESENTATIVE. ;# ;#*********************************************************************** IF(P@NRT_STATE#TELECOMMAND = "PAUSE-ENAB")THEN /NRT TPUT RSUM /CMSMSG,CELIAS,'Procedure F_FL_M_WMT120 has completed' ELSE ENDIF ENDPROC