PROC F_FL_MP_HV0 ;VERSION 1 IF(P@NRT_STATE#TELECOMMAND = "ENABLED")THEN /NRT TPUT PAUS ELSE ENDIF GOTO BEGIN ; ;#*********************************************************************** ;# ****PROCEDURE HEADER**** ;# ;# 1.0 Introduction ;# ;# 1.1 FOT Name: F_FL_MP_HV0 ;# MMS-F Name: ;# SUM Issue: ;# Simulator Validation Status: ;# ;# 1.2 Date Created: 02-OCT-95 ;# Revision: ;# ;# 1.3 Change Description: ;# ;# None. ;# ;# 1.4 Point of Contact: CCAZEAU ATSC/SOHO 286-6374 ;# FOT Author: BSAPPER ATSC/SOHO 286-4799 ;# CELIAS Author: AGALVIN UMD 301-405-6208 ;# ;#*********************************************************************** ;# 2.0 Description ;# ;# 2.1 Narrative Decription ;# ;# SET MTOF HIGH VOLTAGE POWER SUPPLIES TO ;# LOWEST VOLTAGE LEVEL, DISABLED, LIMIT/DELTA=0/0 ;# ;# 2.2 Intended Use: ;# ;# Put CELIAS MTOF sensor into a safe high voltage ;# configuration of ALL OFF, without changing modes. ;# ;# 2.3 Duration: TBD ;# ;# 2.4 References: ;# ;#*********************************************************************** ;# 3.0 Instructions for Use: ;# ;# 3.1 Parameters Required ;# ;# None ;# ;# 3.2 Critical Activities ;# ;# NONE ;# ;# 3.3 Special Constraints or Activities ;# ;# NONE ;# ;# ************************************************************************* ;# 4.0 STEPS: BEGIN: IF(P@CMD_STATE#TELECOMMAND = "AVAILABLE") THEN ELSE /CLEAR ;Clearing the Command Buffer. ENDIF ;# 4.1 Set all MTOF high volages to lowest voltage level WAIT ;NOTE VALUE OF FSDTCOK (command OK counter) /FBMPM,0000 ;PM MCP power supply to level 0 /FBMPE,0000 ;PM E/Q power supply to level 0 /FBMWE,0000 ;MAIN WAVE power supply to level 0 /FBMVF,0080 ;MAIN Vf power supply to level 128 = 0kV /FBMSM,0000 ;MAIN Start MCP power supply to level 0 /FBMNM,0000 ;MAIN Neutral MCP power supply to level 0 /FBMIM,0000 ;MAIN Ion MCP power supply to level 0 /FBMHV,0000 ;MAIN Hyperbola power supply to level 0 WAIT ;VERIFY BUFFER CONTENTS /SEND WAIT ;VERIFY FSDTCOK HAS INCREASED BY 8. NOTE NEW VALUE. ;# 4.2 Set all MTOF high voltage limits and deltas to 0 /FBMLIMPM,0000 ;PM MCP power supply delta/limit = 0,0 /FBMLIMPE,0000 ;PM E/Q power supply delta/limit = 0,0 /FBMLIMWE,0000 ;MAIN WAVE power supply delta/limit = 0,0 /FBMLIMVF,0000 ;MAIN Vf power supply delta/limit = 0,0 /FBMLIMSM,0000 ;MAIN Start MCP power supply delta/limit = 0,0 /FBMLIMNM,0000 ;MAIN Neutral MCP power supply delta/limit = 0,0 /FBMLIMIM,0000 ;MAIN Ion MCP power supply delta/limit = 0,0 /FBMLIMHV,0000 ;MAIN Hyperbola power supply delta/limit = 0,0 WAIT ;VERIFY BUFFER CONTENTS /SEND WAIT ;VERIFY FSDTCOK HAS INCREASED BY 8. NOTE NEW VALUE. ;# 4.3 Disable all MTOF high voltages /FBMDISI,00FF ;disable ALL MTOF high voltages, MAIN AND PM WAIT ;VERIFY BUFFER CONTENTS /SEND WAIT ;VERIFY FSDTCOK HAS INCREASED BY 1. WAIT UNTIL(P@CMD_STATE#TELECOMMAND = "AVAILABLE") ;#*********************************************************************** ;# 5.0 Final Constraints ;# ;# NONE ;# ;#*********************************************************************** IF(P@NRT_STATE#TELECOMMAND = "PAUSE-ENAB")THEN /NRT TPUT RSUM /CMSMSG,CELIAS,'Procedure F_FL_MP_HV0 has completed' ELSE ENDIF ENDPROC