PROC H_FL_FOBS ;Version 3 GOTO BEGIN ; ;#************************************************************************** ;# ****PROCEDURE HEADER**** ;# ;# 1.0 Introduction ;# ;# 1.1 FOT Name: H_FL_FOBS ;# MMS-F Name: H_FL_FOB ;# SUM Issue: N/A ;# Simulator Validation Status: Validated ;# ;# 1.2 Date Created: 7 MAR 1995 TL ;# Revision: 1) 1 MAY 1995 TL ;# 2) 11 Aug 95 TL ;# 3) 25 Oct 95 TL ;# ;# 1.3 Change Description: ;# ;# 1) Changed WAITs to check raw, not discrete, values. ;# 2) Changed name to _FL_ (FLight ready). ;# 3) Added version number, comments. ;# ;# 1.4 Point of Contact: T. LA FAVE ;# FOT Author: T. LA FAVE ATSC/SOHO 286-4799 ;# ;#************************************************************************** ;# 2.0 Description ;# ;# 2.1 Narrative Description ;# ;# This module switches EPHIN from STANDBY to nominal ;# observation mode. The module is self-standing and ;# can be used independently whenever this transition ;# is necessary. ;# ;# 2.2 Intended Use: ;# ;# ;# ;# 2.3 Duration: 4 min. ;# ;# 2.4 References: ;# Page h_cepac2 ;#************************************************************************** ;# 3.0 Instructions for Use: ;# ;# 3.1 Parameters Required ;# ;# None ;# ;# 3.2 Critical Activities ;# ;# None ;# ;# 3.3 Special Constraints or Activities ;# ;# None ;#************************************************************************** ;# 4.0 STEPS: BEGIN: IF (P@CMD_STATE#TELECOMMAND = "AVAILABLE") THEN ELSE /CLEAR ;Clearing the Command Buffer. ENDIF WAIT UNTIL (HSFMODE = 0) ; wait for HSFMODE to go to STANDBY /HBFNMODE ; EPHIN NOMINAL mode /HBFAPDON ; Switch detectors A-G on. WAIT ; Verify command buffer contents /SEND WAIT UNTIL ((HSFMODE= 1) AND (HSFPDAF= 1) AND (HSFPDG= 1)) ;#************************************************************************** ;# 5.0 Final Constraints ;# ;# None ;# ;#************************************************************************** ENDPROC