PROC L_FL_CONFRELS ;Version 3 GOTO BEGIN ; ;#************************************************************************** ;# ****PROCEDURE HEADER**** ;# ;# 1.0 Introduction ;# ;# 1.1 FOT Name: L_FL_CONFRELS ;# MMS-F Name: ConfRel ;# SUM Issue: ;# Simulator Validation Status: ;# ;# 1.2 Date Created: 01/18/95 ;# Revision: 1. 03/14/95 ;# 2. 04/18/95 ;# 3. 10/24/95 ;# 1.3 Change Description: ;# ;# 1. Reformat of the steps in the section VI. ;# Added Command LBCHBON - COB bias heaters on, and TM check ;# LSCHBR - COB bias heaters on. ;# Corrected TM check LKORATE to LKOSCRAT. ;# 2. Removed TM check ESECMR is not applied, and moved TM check ;# LKOSCRAT to procedure l_ts_contboot. ;# 3. Changed proc's name from TS to FL, there is no TSTOL changes ;# and no further input from PI since GSCT#3. ;# ;# 1.4 Point of Contact: CCazeau ;# ;# FOT Author: C.Q ATSC/SOHO 286-4799 ;# ;#************************************************************************** ;# 2.0 Description ;# ;# 2.1 Narrative Description ;# ;# This procedure will configures the LEB controlled relays. ;# ;# 2.2 Intended Use: ;# ;# LEB controlled relays configuration ;# ;# 2.3 Duration: TBD ;# ;# 2.4 References: LASCO/EIT EXPERIMENT GUIDE ;# ;#************************************************************************** ;# 3.0 Instructions for Use: ;# ;# 3.1 Parameters Required ;# ;# None ;# ;# 3.2 Critical Activities ;# ;# None ;# ;# 3.3 Special Constraints or Activities ;# ;# The LEB power must have been commanded on experiment power ;# and +31v should be off. ;#************************************************************************** ;# 4.0 STEPS: BEGIN: IF (P@CMD_STATE#TELECOMMAND = "AVAILABLE") THEN ELSE /CLEAR ;Clearing the Command Buffer. ENDIF ;**************** PRELIMINARY VERIFICATIONS **************** SV P@LSI31VRC ;Verify (EXP +31V COMMANDED) parameter is in "OFF" position SV P@LSIEXPRC ;Verify (Experiment Power) is in "OFF" position ASK "IS INSTRUMENT CONTROL BOARD A TO BE BOOTED? (Y/N)" ANSWER = %UPPER(ANSWER) IF (ANSWER .EQ. "Y") THEN /LBIAON ;Select instrument controller board A /LB1MAON ;M1 CONTROL ELECTRONICS A ON /LB2PAON ;PES SIDE A ON WAIT ;Verify contents of command buffer /SEND WAIT 30 ;Wait for 30 seconds WAIT UNTIL (P@LSIAR = "ON") ;IC-A SELECTED WAIT UNTIL (P@LS2PAR = "ON") ;PES-A ON WAIT UNTIL (P@LS1MAR = "ON") ;M1-A ON ENDIF ASK "IS INPUT PARAMETER IS IC-B? (Y/N)" ANSWER = %UPPER(ANSWER) IF (ANSWER .EQ. "Y") THEN /LBIBON ;Select instrument controller board B /LB1MBON ;M1 CONTROL ELECTRONICS B ON /LB2PBON ;PES SIDE B ON WAIT ;Verify contents of command buffer /SEND WAIT 30 ;Wait for 30 seconds WAIT UNTIL (P@LSIBR = "ON") ;IC-B SELECTED WAIT UNTIL (P@LS1MBR = "ON") ;M1-B ON WAIT UNTIL (P@LS2PBR = "ON") ;PES-B ON ENDIF /LBHMOF ;MAKE UP HEATERS ALL OFF WAIT ;Verify contents of command buffer /SEND WAIT 30 ;Wait for 30 seconds WAIT UNTIL (P@LS1CMR = "OFF") ;C1 CAMERA MU HEATER OFF WAIT UNTIL (P@LS2CMR = "OFF") ;C2 CAMERA MU HEATER OFF WAIT UNTIL (P@LS3CMR = "OFF") ;C3 CAMERA MU HEATER OFF WAIT UNTIL (P@LS1MFR = "OFF") ;FP MU HEATER OFF /LB1FON ;FABRY-PEROT POWER RELAY ON /LB1CON ;C1 CAMERA ON /LB2CON ;C2 CAMERA ON /LB3CON ;C3 CAMERA ON /EBECON ;EIT CAMERA ON /LB1RDON ;CAL LAMP DETECTOR RELAY ON /LBCBSON ;BORESIGHTER RELAY ON WAIT ;Verify contents of command buffer /SEND WAIT 30 ;Wait for 30 seconds WAIT UNTIL (P@LS1CMR = "OFF") ;C1 CAMERA MU HEATER OFF WAIT UNTIL (P@LS2CMR = "OFF") ;C2 CAMERA MU HEATER OFF WAIT UNTIL (P@LS3CMR = "OFF") ;C3 CAMERA MU HEATER OFF WAIT UNTIL (P@LS1MFR = "OFF") ;FP MU HEATER OFF WAIT UNTIL (P@LS1FR = "ON") ;FP RELAY ON WAIT UNTIL (P@LS1CR = "ON") ;C1 CAMERA ON WAIT UNTIL (P@LS2CR = "ON") ;C2 CAMERA ON WAIT UNTIL (P@LS3CR = "ON") ;C3 CAMERA ON WAIT UNTIL (P@ESECR = "ON") ;EIT CAMERA ON WAIT UNTIL (P@LS1RR = "ON") ;CAL LAMP DETECTOR ON WAIT UNTIL (P@LSCBR = "ON") ;BORESIGHTER ON ASK "DO YOU WANT TO TURN ON THE COB BIAS HEATERS? (Y/N)" ANSWER = %UPPER(ANSWER) IF (ANSWER .EQ. "Y") THEN /LBCHBON ;COB BIAS HEATERS ON WAIT ;Verify contents of command buffer /SEND WAIT 30 ;Wait for 30 seconds WAIT UNTIL (P@LSCHBR = "ON") ;COB BIAS HEATERS ON ELSE ;(COB BIAS HEATERS ARE NOT TO BE TURNED ON) /LBCHBOF ;COB BIAS HEATERS OFF WAIT ;Verify contents of command buffer /SEND WAIT 30 ;Wait for 30 seconds WAIT UNTIL (P@LSCHBR = "OFF") ;COB BIAS HEATERS OFF ENDIF ;#************************************************************************** ;# 5.0 Final Constraints ;# ;# TBD ;# ;#************************************************************************** ENDPROC