PROC M_FL_V_LIM ;Version 9 GOTO BEGIN ; ;#************************************************************************** ;# ****PROCEDURE HEADER**** ;# ;# 1.0 Introduction ;# ;# 1.1 FOT Name: M_FL_V_LIM ;# MMS-F Name: N/A ;# SUM Issue: N/A ;# Simulator Validation Status: ;# ;# 1.2 Date Created: 11/29/95 GJ ;# Revision: 1. 12/02/95 GJ ;# 2. 12/09/95 CQ ;# 3. 12/13/95 TL ;# 4. 12/19/95 CQ ;# 5. 01/28/96 BB ;# 6. 04/03/96 CQ ;# 7. 08/26/96 BB ;# 8. 13-NOV-96 RcJ ;# 9. 12/03/96 KEH ;# ;# 1.3 Change Description: ;# 1. Corrected value from M+15 to M-15 and ;# voltages 13.5/14.0. ;# 2. Corrected mnemonic M+15PC1N to M-15PC1N. ;# 3. Changed limits, turned off those at end. ;# 4. Correct typo for mnemonics MDFDCLN --> MSFDCLN, and ;# MDFDCLR --> MSFDCLR. ;# 5. Removed WAIT statement. ;# 6. Change of limits according to PI request. ;# 7. Correct limits for QTMI1C. ;# 8. Change dlims for M+75LT, per OCD#411. ;# 9. Changed MTOPTS1 yellow high limit, per OCD #438. ;# ;# 1.4 Point of Contact: ;# FOT Author: GJENNINGS ;# ;#************************************************************************** ;# 2.0 Description ;# ;# 2.1 Narrative Description ;# ;# This procedure sets and enables limit checking for the ;# spacecraft power systems parameters and MDI internal ;# voltage monitors. ;# ;# 2.2 Intended Use: ;# ;# Establish limits for MDI S/C and internal voltages which ;# may identify hardware risk issues if violated. ;# ;# 2.3 Duration: ;# ;# 2.4 References: ;# ;#************************************************************************** ;# 3.0 Instructions for Use: ;# ;# 3.1 Parameters Required ;# ;# None ;# ;# 3.2 Critical Activities ;# ;# ;# ;# 3.3 Special Constraints or Activities ;# ;# MDI in SLEEP or higher mode. This procedure should ;# be completed as part of the MDI power on. All values ;# TBR. Red action limits on m+5cm and m+5pc2n. ;#************************************************************************** ;# 4.0 STEPS: ;# ; BEGIN: ; ; Set the limits for the S/C power system ; parameters an MDI internal voltage ; monitors. ; ; ; Set the voltage limits for S/C monitors ; LIM CHANGE M+5PC1N EU 1 LIMVAL 4.6 5.1 5.6 6.0 LIM CHANGE M+5PC1R EU 1 LIMVAL 4.6 5.1 5.6 6.0 LIM CHANGE M+5PC2N EU 1 LIMVAL 4.6 5.1 5.6 6.0 LIM CHANGE M+5PC2R EU 1 LIMVAL 4.6 5.1 5.6 6.0 LIM CHANGE M+15PC1N EU 1 LIMVAL 14.5 15.0 15.6 16.1 LIM CHANGE M+15PC1R EU 1 LIMVAL 14.5 15.0 15.6 16.1 LIM CHANGE M+15PC2N EU 1 LIMVAL 14.0 14.25 14.75 15.0 LIM CHANGE M+15PC2R EU 1 LIMVAL 14.0 14.25 14.75 15.0 LIM CHANGE M-15PC1N EU 1 LIMVAL -15.7 -15.2 -14.7 -14.2 LIM CHANGE M-15PC1R EU 1 LIMVAL -15.7 -15.2 -14.7 -14.2 LIM CHANGE M-15PC2N EU 1 LIMVAL -15.5 -15.1 -14.3 -14.0 LIM CHANGE M-15PC2R EU 1 LIMVAL -15.5 -15.1 -14.3 -14.0 ; ; ; Set the voltage limits fot MDI monitors ; LIM CHANGE M+5AE EU 1 LIMVAL 4.5 5.0 5.5 6.0 LIM CHANGE M+5CM EU 1 LIMVAL 4.5 5.0 5.5 6.0 LIM CHANGE M+5IP EU 1 LIMVAL 4.0 4.5 5.6 6.0 LIM CHANGE M+15AE EU 1 LIMVAL 13.7 14.2 14.9 15.5 LIM CHANGE M+15CM EU 1 LIMVAL 14.5 14.9 15.6 16.0 LIM CHANGE M+15HTR EU 1 LIMVAL 14.0 14.5 17.0 18.0 LIM CHANGE M+15MTR EU 1 LIMVAL 13.5 14.0 18.0 18.5 LIM CHANGE M+30CM EU 1 LIMVAL 28.0 30.0 35.0 37.0 LIM CHANGE M+75LT EU 1 LIMVAL 70.0 73.0 83.0 88.0 DLIM CHANGE M+75LT EU 1 LIMVAL 1.5 1.0 ;per ocd 411 LIM CHANGE M-15AE EU 1 LIMVAL -15.5 -15.1 -14.3 -14.0 LIM CHANGE M-15CM EU 1 LIMVAL -16.0 -15.5 -14.7 -14.0 LIM CHANGE MIPWA EU 1 LIMVAL 0.7 1 1.6 2.0 LIM CHANGE MIPWB EU 1 LIMVAL N -0.05 0.5 1.0 LIM CHANGE MIAEMTR EU 1 LIMVAL N -0.05 0.3 0.35 LIM CHANGE MTOPTS1 EU 1 LIMVAL 5 10 47.5 50 LIM CHANGE MTOPTS2 EU 1 LIMVAL 5 10 35 40 LIM CHANGE MTOPTS3 EU 1 LIMVAL 5 10 35 40 LIM CHANGE MTOPTS4 EU 1 LIMVAL 30 33 41 43 LIM CHANGE MTOPTS5 EU 1 LIMVAL 30 33 41 43 LIM CHANGE MTOPTS6 EU 1 LIMVAL -110 -105 40 45 LIM CHANGE MTOPTS7 EU 1 LIMVAL 5 10 35 40 LIM CHANGE MTOPTS8 EU 1 LIMVAL -5 0 35 40 LIM CHANGE MTOPTS9 EU 1 LIMVAL 5 10 35 40 LIM CHANGE MTOPTS10 EU 1 LIMVAL 5 10 35 40 LIM CHANGE MTOPTS11 EU 1 LIMVAL -215 -210 35 40 LIM CHANGE MTOPTS12 EU 1 LIMVAL 5 10 35 40 LIM CHANGE MTOPTS13 EU 1 LIMVAL 5 10 35 40 LIM CHANGE MTOPTS14 EU 1 LIMVAL 5 10 35 40 LIM CHANGE MTOPTS15 EU 1 LIMVAL 5 10 35 40 LIM CHANGE MTOPTS16 EU 1 LIMVAL 5 10 35 40 LIM CHANGE MTEPTS1 EU 1 LIMVAL -5 0 40 45 LIM CHANGE MTEPTS2 EU 1 LIMVAL -5 0 40 45 LIM CHANGE MTEPTS3 EU 1 LIMVAL -5 0 40 45 LIM CHANGE MTEPTS4 EU 1 LIMVAL -20 -15 40 45 LIM CHANGE MUHPOBRG EU 1 LIMVAL N .2 .4 N LIM CHANGE MUHPOLOP EU 1 LIMVAL N 2.0 2.5 N LIM CHANGE MXAM1POS EU 1 LIMVAL -370 -350 350 370 LIM CHANGE MXAM2POS EU 1 LIMVAL -370 -350 350 370 LIM CHANGE QTMI1A EU 1 LIMVAL 5 10 35 40 LIM CHANGE QTMI1B EU 1 LIMVAL 5 10 35 40 LIM CHANGE QTMI1C EU 1 LIMVAL 5 10 41 43 LIM CHANGE QTMI1D EU 1 LIMVAL -110 -105 40 45 LIM CHANGE QTMI2 EU 1 LIMVAL -15 -5 40 45 ; LIM OFF MULTXMAX LIM OFF MULTYMAX LIM OFF MULTDIO1 LIM OFF MULTDIO2 LIM OFF MULTDIO3 LIM OFF MULTDIO4 LIM OFF MTSQOPT1 LIM OFF MTSQOPT4 LIM OFF MTSQOPT5 LIM OFF MTSQOPT6 LIM OFF MULTPZT1 LIM OFF MULTPZT2 LIM OFF MULTPZT3 LIM OFF MULTXAVE LIM OFF MULTYAVE LIM OFF MUHOPCTL LIM OFF MUHROCTL LIM OFF MXHPOREF LIM OFF MXSP1N LIM OFF MXSP1R ; LIM OFF MIAEMTR LIM OFF MKFDFUNC LIM OFF MKFDTIME LIM OFF MKFDSTAT LIM OFF MKFDMOVE LIM OFF MKFDOPN1 LIM OFF MKFDOPN2 LIM OFF MSFDOPN LIM OFF MKFDMTR1 LIM OFF MKFDMTR2 LIM OFF MSFDOPR LIM OFF MSFDCLN LIM OFF MSFDCLR ;#************************************************************************** ;# 5.0 Final Constraints ;# ;# None ;# ;#************************************************************************** ENDPROC