PROC m_fl_vlimit ;Version 2 GOTO BEGIN ; ;#************************************************************************** ;# ****PROCEDURE HEADER**** ;# ;# 1.0 Introduction ;# ;# 1.1 FOT Name: M_FL_VLIMIT ;# MMS-F Name: ;# SUM Issue: ;# Simulator Validation Status: ;# ;# 1.2 Date Created: 9/27/94 ;# Revision: 1. 5-26-95 ;# 2. 11/18/95 GJ ;# ;# 1.3 Change Description: ;# ;# 1. Corrected syntax errors ;# 2. Changed name convention from m_ts_* to m_fl_*. ;# ;# 1.4 Point of Contact: ;# FOT Author: RRowe ATSC/SOHO 805-3642 ;# ;#************************************************************************** ;# 2.0 Description ;# ;# 2.1 Narrative Description ;# ;# This procedure sets and enables limit checking for the ;# spacecraft power systems parameters and MDI internal ;# voltage monitors. ;# ;# 2.2 Intended Use: ;# ;# Establish limits for MDI S/C and internal voltages which ;# may identify hardware risk issues if violated. ;# ;# 2.3 Duration: TBD ;# ;# 2.4 References: ;# ;#************************************************************************** ;# 3.0 Instructions for Use: ;# ;# 3.1 Parameters Required ;# ;# None ;# ;# 3.2 Critical Activities ;# ;# TBD ;# ;# 3.3 Special Constraints or Activities ;# ;# MDI in SLEEP or higher mode. This procedure should ;# be completed as part of the MDI power on. All values ;# TBR. Red action limits on m+5cm and m+5pc2n. ;#************************************************************************** ;# 4.0 STEPS: ;# ; BEGIN: IF (P@CMD_STATE#TELECOMMAND = "AVAILABLE") THEN ELSE /CLEAR ;Clearing the Command Buffer. ENDIF ; ; 'GO' to set the limits for the S/C power ; system parameters an MDI internal voltage WAIT; monitors. ; ; ; Set the voltage limits for S/C monitors ; LIM CHANGE M+5PC1N EU 1 LIMVAL 4.0 4.5 6.5 7.0 LIM CHANGE M+15PC1N EU 1 LIMVAL 13.0 14.0 17.5 18.0 LIM CHANGE M-15PC1N EU 1 LIMVAL -17.0 -16.0 -14.0 -13.0 LIM CHANGE M+5PC2N EU 1 LIMVAL 4.0 4.5 6.5 7.0 LIM CHANGE M+15PC2N EU 1 LIMVAL 13.0 14.0 17.0 18.0 LIM CHANGE M-15PC2N EU 1 LIMVAL -17.0 -16.0 -14.0 -13.0 ; ; ; Set the voltage limits fot MDI monitors ; LIM CHANGE M+5IP EU 1 LIMVAL 4.0 4.5 6.0 7.0 LIM CHANGE M+5CM EU 1 LIMVAL 4.0 4.5 6.0 7.0 LIM CHANGE M+15CM EU 1 LIMVAL 13.0 14.0 17.0 18.0 LIM CHANGE M-15CM EU 1 LIMVAL -17.0 -16.0 -14.0 -13.0 LIM CHANGE M+30CM EU 1 LIMVAL 25.0 27.0 38.0 40.0 LIM CHANGE M+5AE EU 1 LIMVAL 4.0 4.5 6.0 7.0 LIM CHANGE M+15AE EU 1 LIMVAL 13.0 14.0 17.0 18.0 LIM CHANGE M-15AE EU 1 LIMVAL -17.0 -16.0 -14.0 -13.0 LIM CHANGE M+15MTR EU 1 LIMVAL 13.0 14.0 19.0 20.0 LIM CHANGE M+15HTR EU 1 LIMVAL 13.0 14.0 19.0 20.0 LIM CHANGE M+75LT EU 1 LIMVAL 65.0 70.0 80.0 85.0 ; ; ; Turn the MDI voltage limits ON ; ; LIM ON M+5PC1N LIM ON M+15PC1N LIM ON M-15PC1N LIM ON M+5PC2N LIM ON M+15PC2N LIM ON M-15PC2N LIM ON M+5IP LIM ON M+5CM LIM ON M+15CM LIM ON M-15CM LIM ON M+30CM LIM ON M+5AE LIM ON M+15AE LIM ON M-15AE LIM ON M+15MTR LIM ON M+15HTR LIM ON M+75LT ; ;#************************************************************************** ;# 5.0 Final Constraints ;# ;# TBD ;# ;#************************************************************************** ENDPROC